Few manufacturers can show a psychrometric laboratory of their own, let alone an NABL-accredited one. Ezentech tests what it builds — cooling capacity, power input, ISEER — and hands the result to the partner.

The quality file

Tested like it ships.
Certified like it matters.

A procurement head buying an air conditioner for their brand is really buying a number: the rated ISEER on the label. That number comes from a psychrometric test, and an NABL-accredited laboratory is what makes it defensible.

Ezentech runs that laboratory itself, inside an ISO 9001 quality system and an ISO 14001 environmental system, and manufactures BIS-certified product ranges.

Accredited psychrometric laboratory
NABL
Quality management system
ISO 9001
Environmental management system
ISO 14001
Certified product ranges
BIS

Credentials, and what each covers

05 credentials

NABL accreditation
Accredited competence of the psychrometric laboratory to measure air-conditioner performance — the basis for a rated capacity and ISEER a buyer can rely on.
ISO 9001
The quality management system the plants operate under: documented processes, in-line checks, corrective action and audit.
ISO 14001
The environmental management system behind responsible manufacturing — from refrigerant handling to waste and energy use.
Learn more
BIS certification
Product certification for the ranges Ezentech manufactures for brand partners.
LG "Role Model Supplier"
Supplier recognition from a brand Ezentech builds for — earned on the line, not the letterhead.
Learn more

Inside the lab

What a psychrometric
test measures.

A citable summary of the test behind the rated figures on every Ezentech specification sheet — and the ISEER values it produced.

Measured parameters

05 parameters

Cooling capacity
The heat removed from the indoor air per hour, in watts — 3,400 to 6,300 W across the sheet — measured with indoor and outdoor rooms held at controlled temperature and humidity.
Power input
The electrical power the unit draws while delivering that capacity; with capacity it gives the efficiency ratio.
ISEER
Indian Seasonal Energy Efficiency Ratio — cooling delivered per unit of electricity over a full Indian cooling season, as rated under the BEE star-labelling scheme. Higher is more efficient.
Airflow
The indoor air volume delivered, in m³/h — 850 to 1,100 m³/h on the sheet — set by the fan, the coil's resistance and the fascia's intake and outlet.
Sensible and latent split
With humidity controlled, the test separates dry-bulb cooling from dehumidification — the difference between a room that feels cool and one that feels dry.
Rated ISEER on the sheet
ParameterValue
Rated ISEER, as printed
Split 3-star (12K, 17K, 18K, 22K)4.35W/W
Split 5-star (17K, 18K)5.65W/W
Window 3-star (18K)3.35W/W
Window 5-star (22K)5.20W/W

Values as printed on the manufacturer specification sheet. See every model.

Test protocol

Five checkpoints
before dispatch.

Process

05 steps

  1. Incoming component checks

    Coils, compressors, fan motors and moulded parts are checked against specification before they reach the line.
  2. In-line quality control

    Assembly, brazing and charging are inspected at station; leak tests close every refrigerant circuit.
  3. Psychrometric performance test

    Cooling capacity, power input and ISEER measured under controlled temperature and humidity in the NABL-accredited lab.
  4. Electrical and safety test

    Insulation, earth continuity and functional checks on every unit.
  5. Pre-dispatch audit

    Finished, packed units audited against the sheet and the partner's requirement before they leave the plant.

On the floor

NABL-accredited psychrometric laboratory · Greater NoidaFig 01

Recognition

Recognised by the brands we build for

LG “Role Model Supplier” — earned on the line, not the letterhead.

Quality & Certifications

Buyer questions

Before you
write the RFQ.

Frequently asked

04 questions

What is NABL accreditation?

NABL (National Accreditation Board for Testing and Calibration Laboratories) accredits a laboratory's competence to carry out specific tests. For Ezentech's psychrometric lab it means the capacity and ISEER measurements are made under an accredited, audited method.

What does a psychrometric test measure?

With indoor and outdoor conditions held at controlled temperature and humidity, the test measures the unit's cooling capacity, its power input and the resulting efficiency ratio, and the airflow delivered — the figures printed on the specification sheet and the BEE label.

What is the difference between a 3-star and a 5-star unit?

The BEE star band is set by rated ISEER. On the Ezentech sheet, 3-star split models are rated 4.35 and 5-star models 5.65; window models are rated 3.35 (3-star) and 5.20 (5-star).

Are test results shared with brand partners?

Performance results for a partner's programme are part of the engagement; how they are reported is agreed in the RFQ.

Planning a programme that needs testing? Send the requirement — capacity, volume, chassis — and we will come back with a production plan.

Start the conversation

Let’s build
your next range.

From spec to shipped — send us your requirement and get a structured, engineering-backed quote.

OEM / ODM · Private label · Contract manufacturing